FAQs
Here are quick answers to the most common questions from our clients.Want more answers?Contact us or explore further!
Can’t find the answer? Please contact us
The industrial steam boiler operating system consists of the boiler proper and auxiliary accessories. The boiler system generates high-temperature steam that is delivered to the production workshop through steam pipes for industrial production. When using an industrial boiler, the selection of auxiliary equipment is particularly important, as it directly affects boiler operating conditions. The accessories, their functions, and the selection method are described below.
I. Industrial steam boiler auxiliary accessories
Industrial steam boiler accessories include the burner, make-up water pump, control cabinet, economizer, condenser, steam header, boiler water treatment equipment, instruments and valves, etc. The functions of each device are described below:
II. Steam boiler selection
When selecting a steam boiler, the main considerations are the boiler fuel and steam pressure. The fuel must meet local environmental requirements, while the steam pressure must be considered based on production needs. Boiler installation is the final step of boiler procurement; after installation and acceptance, the boiler can be put into operation.
The YY(Q)W series gas/oil-fired organic heat carrier boiler adopts a three-pass circular coil structure. The coil ends use a necked-down coil design that effectively protects the furnace wall at the boiler end. Equipped with an advanced burner, the boiler operates fully automatically.
After the fuel is ignited by the burner in an oil/gas-fired thermal oil boiler, the flame fills the circular coil and transfers radiant heat through the coil wall — this is the first pass. The high-temperature flue gas produced by combustion converges at the rear furnace door and turns into the second pass, i.e., the convective tube bank area. After convective heat exchange, the flue gas temperature gradually decreases until it reaches the front furnace door, where it turns into the third-pass tube bank area, then passes through the economizer into the chimney and is discharged to the atmosphere. The boiler is delivered as a complete unit; once positioned on site, it only needs to be connected to the gas (or oil) supply and electricity to be put into operation. The boiler heating surface consists of four parts: the furnace radiation heating surface, the first convective tube bank heating surface, the second convective tube bank heating surface, and the economizer (waste heat boiler).
I. Key points for hot water boiler selection
When selecting a hot water boiler, first accurately calculate the building heat load to ensure capacity matching. Second, choose the boiler type based on available energy sources (such as natural gas, electricity, etc.), and give priority to energy-saving products with high thermal efficiency and intelligent temperature control. In addition, installation space, operating costs, and local environmental requirements are also key deciding factors.
II. Selection process flowchart
Requirements analysis → Heat load calculation → Boiler type selection → Brand comparison → Installation plan design → Cost-benefit analysis → Final decision
III. Core advantages
‘WNS boiler’ refers to a very common model designation for oil/gas-fired steam or hot water boilers. This designation is named according to the Chinese industrial boiler model classification standard, and each letter and number has a specific meaning.
WNS can be broken down into three parts:
Main features of WNS boilers:
I. Key boiler water quality control indicators
Boiler feed water quality control mainly focuses on the following key chemical indicators to prevent scale formation, reduce corrosion, and ensure steam purity.
To meet the above water quality requirements, a series of treatments must be applied to the raw water.
Water quality monitoring and blowdown management
For boilers using softened water as make-up, the normal blowdown rate should not exceed 10%.
For boilers using demineralized water as make-up, the blowdown rate should not exceed 2%. It is also recommended to recover heat from continuous blowdown water to improve energy utilization.
The fuel consumption of a biomass thermal oil heater is proportional to the boiler capacity (thermal power). The core relationship is: the larger the boiler capacity, the more fuel is consumed to provide the same amount of heat.
The specific fuel consumption value is determined by the following formula, where any change in a variable affects the final result:
Hourly fuel consumption = Boiler heat output ÷ Fuel calorific value ÷ Boiler thermal efficiency
Boiler capacity and thermal power: In the thermal oil heater industry, the rated heating output of a 1-ton boiler generally corresponds to 600,000 kcal/hour. This is the basis for calculation.
Fuel calorific value: This is the variable with the greatest impact. The calorific values of different biomass fuels vary greatly, for example:
Common biomass pellet fuels have a calorific value of 3,800–4,200 kcal/kg.
Fuels such as rice husk and straw have lower calorific values, about 3,000–3,500 kcal/kg.
Boiler thermal efficiency: This is an indicator of the boiler’s efficiency in converting the chemical energy of the fuel into thermal energy. At present, the design thermal efficiency of most biomass thermal oil heaters on the market is between 80% and 90%.
If the specific fuel calorific value and boiler efficiency are unknown, a rough estimate of approximately 170 kg of biomass pellets consumed per hour per 1-ton boiler can be used.
The most fundamental difference between low-nitrogen boilers and conventional boilers lies in nitrogen oxide (NOx) emissions. Through a series of advanced technologies, low-nitrogen boilers can greatly reduce the generation of harmful gases and are the mainstream choice under current environmental policies.
NOx emissions: Low-nitrogen boilers can be controlled within 30–80 mg/m³, and in some regions even below 30 mg/m³. Conventional boilers generally emit between 80–150 mg/m³.
Thermal efficiency: Low-nitrogen boilers are usually above 98%. Some condensing products can exceed 100% thermal efficiency (calculated on the lower heating value basis). Conventional boilers are relatively lower, generally around 92%.
Core technologies: Low-nitrogen boilers adopt low-NOx burners, flue gas recirculation (FGR), fully premixed combustion, and other technologies to suppress NOx generation by lowering flame temperature and oxygen concentration. Conventional boilers use traditional diffusion burners with high combustion temperatures and sufficient oxygen supply, thus generating large amounts of NOx.
Operating costs: Low-nitrogen boilers, thanks to high thermal efficiency, reduce gas consumption and save considerable fuel costs over long-term operation. Conventional boilers are relatively higher, with energy utilization efficiency lower than that of low-nitrogen boilers.
Environmental compliance: Low-nitrogen boilers comply with strict domestic environmental protection policies and are the mainstream choice for new boilers and the retrofit of old boilers. Conventional boilers, in most key environmental protection cities, no longer meet current emission standards and face mandatory retrofitting or phase-out.
To accurately calculate fuel consumption, you first need to understand the calculation formula:
Hourly boiler fuel consumption = Boiler thermal power / (Fuel calorific value × Boiler thermal efficiency)
Taking a 1-ton (600,000 kcal) biomass steam boiler as an example, substitute common parameters for calculation:
Unit conversion: A 1-ton boiler produces 600,000 kcal of heat per hour.
Fuel calorific value: The calorific value of biomass pellets is not fixed. Generally, the calorific value of mixed hardwood pellets is around 4,000 kcal/kg, while lower-calorific-value pellets such as peanut shell or straw pellets may be around 3,500 kcal/kg.
Boiler thermal efficiency: This is key to reflecting the manufacturer’s technical strength. Old boilers may have an efficiency of only 70%–80%, while new biomass boilers such as the SZL series from Henan Yuanda Boiler can generally achieve a design thermal efficiency of over 85%.
If using high-quality hardwood pellets with a calorific value of 4,000 kcal and leveraging high-efficiency combustion technology:
Hourly consumption: 600,000 kcal ÷ (4,000 kcal/kg × 85%) ≈ 176 kg/hour.
Daily consumption: Based on 24 hours of operation per day, a 1-ton biomass boiler consumes approximately 4.2 tons of biomass pellets per day.
Apart from pellet prices, the boiler’s own efficiency directly determines fuel savings. If you choose a low-quality or inefficient boiler, it will burn several hundred kilograms more pellets per day, which becomes a huge expense over a year.
The WNS series and SZS series gas-fired hot water boilers are star products on the current market.
WNS series (0.35–29 MW): Adopt a horizontal two-pass or three-pass wet-back structure with a large corrugated furnace tube design. This structure not only increases the radiation heating area but also makes fuel combustion more complete. The flue gas heat transfer efficiency is extremely high, ensuring the boiler maintains rated output even in severe cold weather.
SZS series (4.2–56 MW): For large-scale central heating projects, the SZS double-drum longitudinal water-tube boiler is the better solution. It adopts a full membrane water wall design with good sealing and low heat loss, and is especially suitable for large-scale central heating needs in extremely cold regions.
The reasons mainly come from two aspects. First, fuel cost sensitivity. Natural gas price fluctuations directly affect long-term operating costs. Users no longer look only at the initial investment of the boiler, but pay more attention to the actual operating thermal efficiency — saving 10 m³ of natural gas per ton of steam means considerable savings over a year. Second, tightening emission standards. Many key regions in China have tightened NOx emission limits to 50 mg/m³ or even below 30 mg/m³, and conventional combustion technologies find it difficult to stably meet these standards. What enterprises need is not just ‘a boiler that can burn gas’, but a complete solution that balances energy efficiency, emissions, and operational reliability.
Taking the food processing industry as an example, processes such as cooking, sterilization, drying, and heating have high requirements for steam quality, and loads often fluctuate periodically. If piped gas or LNG supply is available locally, configuring a high-efficiency low-nitrogen oil/gas-fired boiler can both meet process temperature requirements and help the factory confidently pass environmental inspections. Therefore, when updating steam systems, many enterprises prioritize understanding the boiler’s measured thermal efficiency, low-nitrogen combustion technology route, and load regulation capability.
When selecting, enterprises should not only look at rated evaporation capacity, but also focus on thermal efficiency, exhaust gas temperature, raw NOx emission concentration, and load regulation ratio. In particular, the matching of the burner and furnace tube, and the control method of flue gas recirculation, directly affect the actual gas consumption and environmental performance in operation. If the boiler structural design is unreasonable, it is prone to flame-out at low load and excessive emissions at high load, adding to operation and maintenance troubles.