The YY(Q)W series gas/oil-fired organic heat carrier boiler adopts a three-pass circular coil structure. The coil ends use a necked-down coil design that effectively protects the furnace wall at the boiler end. Equipped with an advanced burner, the boiler operates fully automatically.
After the fuel is ignited by the burner in an oil/gas-fired thermal oil boiler, the flame fills the circular coil and transfers radiant heat through the coil wall — this is the first pass. The high-temperature flue gas produced by combustion converges at the rear furnace door and turns into the second pass, i.e., the convective tube bank area. After convective heat exchange, the flue gas temperature gradually decreases until it reaches the front furnace door, where it turns into the third-pass tube bank area, then passes through the economizer into the chimney and is discharged to the atmosphere. The boiler is delivered as a complete unit; once positioned on site, it only needs to be connected to the gas (or oil) supply and electricity to be put into operation. The boiler heating surface consists of four parts: the furnace radiation heating surface, the first convective tube bank heating surface, the second convective tube bank heating surface, and the economizer (waste heat boiler).

  1. Safe high-temperature, low-pressure operation: A thermal oil boiler can provide temperatures up to 350°C at low pressure, with system pressure only 1/40–1/80 of that of saturated steam, greatly reducing equipment pressure requirements and improving system safety.
  2. High thermal efficiency and significant energy savings: Modern gas-fired thermal oil boilers generally achieve a thermal efficiency of over 92%; combined with a flue gas waste heat recovery device, overall thermal efficiency can reach over 95%, saving 15%–30% of energy compared to traditional boilers.
  3. Precise temperature control: With an advanced PLC control system, temperature control accuracy of ±1°C can be achieved, meeting the temperature requirements of precision production processes, and is especially suitable for temperature-sensitive industrial processes.
  4. Long system service life: The closed-loop circulation system has no condensate discharge losses. The thermal oil circulates in a closed system, reducing oxygen corrosion and extending the service life of the boiler and piping network.
  5. Low operating costs: No water treatment equipment is required, saving water treatment costs and labor costs; the high degree of automation reduces the number of operators; maintenance is simple and maintenance costs are low.